Air Conditioner & Heat Pump 22-Point Inspection
- Inspect and clean the outdoor condensing unit
- Inspect the indoor coil
- Inspect for visible refrigerant leaks
- Inspect the condensate drain pan
- Inspect the condensate drain line and p-trap
- Inspect wiring and control unit
- Inspect the blower assembly
- Inspect the thermostat operation and programming
- Verify suction and discharge pressure
- Verify supply and return air static pressures
- Inspect safety controls
- Inspect electrical components
- Verify temperature drop (and rise on heat pump)
- Verify correct superheat or sub-cooling
- Verify motor amps
- Clean control panel
- Verify correct voltage to equipment
- Verify blower speed
- Inspect refrigerant lines
- Cycle equipment to verify operation
- Clean or replace filter
Ductless Mini-Split 26-Point Inspection: Outdoor Unit
- Inspect and clean the outdoor condensing unit
- Inspect the indoor coil
- Inspect for visible refrigerant leaks
- Inspect the condensate drain pan
- Inspect the condensate drain line and p-trap
- Inspect wiring and control unit
- Inspect the blower assembly
- Inspect the thermostat operation and programming
- Verify suction and discharge pressure
- Verify supply and return air static pressures
- Inspect safety controls
- Inspect electrical components
- Verify temperature drop (and rise on heat pump)
- Verify correct superheat or sub-cooling
- Verify motor amps
- Clean control panel
- Verify correct voltage to equipment
- Verify blower speed
- Inspect refrigerant lines
- Cycle equipment to verify operation
- Clean or replace filter
- Provide a written diagnostic report of findings
Ductless Mini-Split 26-Point Inspection: Indoor Unit(s)
- Inspect and change batteries in remote if needed
- Inspect and clean filters
- Inspect and clean blower wheel
- Inspect and clean indoor housing
- Inspect and clean condensate line
- Inspect and clean indoor coil
- Verify condensate pump operation
- Verify correct voltage and communication to equipment
- Flush drain line
- Inspect flare connections and and refrigerant lines
- Inspect and clean louvers
- Cycle equipment to verify operation
- Provide a written diagnostic report of findings
Electric Furnace
12-Point Inspection
- Inspect fuses
- Inspect limit switches
- Verify sequencers operating properly
- Verify heat strip amp draw
- Verify continuity of heat strips
- Verify blower motor amps
- Inspect low voltage wiring
- Inspect line voltage wiring
- Clean or replace media filter or clean Electronic Air Cleaner
- Inspect thermostat operation and programming
- Cycle equipment to verify operation
- Provide a written diagnostic report of findings
Gas Furnace 21-Point Inspection
- Inspect wiring and control circuit
- Inspect blower assembly
- Visually inspect heat exchanger(s)
- Check/adjust fuel and air mixture
- Inspect venting and combustion air
- Check flame rectification and clean sensor
- Check/adjust inlet and outlet gas pressure
- Inspect for gas leaks
- Inspect safety controls
- Inspect electrical components
- Verify temperature rise (dry bulb)
- Verify flue temperature and draft
- Verify motor amps
- Clean the control panel, burners, and wipe down equipment
- Verify supply and return air static pressures
- Verify correct voltage to furnace equipment
- Test and measure carbon monoxide
- Inspect thermostat operation and programming
- Clean or replace 4” filter if needed
- Cycle equipment to verify operation
- Provide a written diagnostic report of findings